SHENZHEN LEADERCOLOR SMART CARD CO., LTD

Idioma

How to read user data of UHF RFID tag

fuente:    Publicación Hora:2024-05-15 15:11:16 Autor del artículo:MCZN-RFID

Uhf RFID tags are generally divided into four areas:

【Reserve 】 Address: 0-3; Address: 0-1 Store the 32bit kill password (kill). The default value is 00 00 00 00.
2-3 Almacene la contraseña de acceso de 32 bits. El valor por defecto es 00 00 00 00.
Cuando el área local no está cifrada o encriptada, los datos del área pueden reescribirse a voluntad.

【EPC(EPC Area)】 Address: 2-7; Store the 96bit ID number, which is the area where the data that is normally read out by default by our device is stored. When the local area is not encrypted or encrypted, the data in the area can be rewritten at will.

【TID(TID area)】 Address: 0-5; Store a 48-bit globally unique and unalterable ID number.

【User(User area)】 Address: 0-31; Store 688-bit data. By default, each address is 00 00. If the area is not encrypted or encrypted, data in the area can be rewritten at will.

Las áreas anteriores se explican con el Alien H9, un chip de etiqueta de uso más común, como ejemplo. Los distintos chips, los datos regionales correspondientes y la función real pueden ser diferentes.

Para leer los datos del área de USUARIO, se recomienda que primero mire el protocolo EPC, EPC varias operaciones básicas son leer, escribir, bloquear, matar.
El documento del protocolo es muy detallado, además, si estás haciendo desarrollo de aplicaciones, para operar de acuerdo a la API proporcionada por los fabricantes, necesitas leer las funciones API de los fabricantes.
Si está realizando el desarrollo de la banda base subyacente, debería estar más familiarizado con el protocolo EPC.

Retráctil